INDUSTY NEWS


Fire Smoke Exhaust Fan - GB51251-2015 National Standard Interpretation and Selection


Fire Smoke Exhaust Fan - GB51251-2015 National Standard Full Interpretation

DZ500-4

Fire smoke exhaust fans are the core equipment of building fire protection systems, responsible for expelling toxic smoke and buying time for personnel evacuation during fire incidents. According to the "Code for Fire Protection Design of Buildings" GB50016 and "Technical Standard for Smoke Management and Exhaust Systems in Buildings" GB51251-2015, exhaust facilities must be installed in underground rooms exceeding 100㎡ and evacuation corridors exceeding 20m in length.

Importance of Fire Smoke Exhaust Fans

Core Functions

  • Expel toxic high-temperature smoke during fires (above 280°C)

  • Maintain positive pressure in evacuation passages to prevent smoke intrusion

  • Create favorable conditions for fire rescue

  • Reduce temperature damage to building structural components

Xinfeng fire smoke fans are all certified by the Ministry of Public Security Fire Products Quality Certification Center (CCCF), complying with GB51251-2015 and GB12361-2013 standards.

GB51251-2015 Core Requirements

Key Clauses Interpretation

ClauseRequirementXinfeng Configuration
4.7.2Exhaust fan must operate continuously at 280°C for 30minFireproof materials + high-temperature bearings
4.7.5Fan room fire resistance grade ≥2.0hFireproof partition walls + fire doors
5.2.2Exhaust volume calculated by air change ratePrecise air volume calculation
5.2.8System worst-loop volume ≤10%CFD simulation optimization
6.3.1280°C fire smoke exhaust damper at fan outletStandard eutectic alloy valve

CCCF Certification Requirements

  • Type test report (air volume, pressure, noise, vibration)

  • Fire resistance test (280°C×30min)

  • Electrical safety test (insulation, grounding, leakage current)

  • Certification valid for 5 years, annual supervision inspection

Xinfeng Fire Smoke Fan Products

XFJ-FR Series Fire Smoke Exhaust Fan

ParameterSpecification
CertificationCCCF certified, certificate number verifiable
Temperature280°C continuous operation 30min, no deformation
Air Volume5,000-50,000 m³/h
MaterialCarbon steel/304 stainless steel

XFJ-FR-H Series High-Temperature Fire Fan

ParameterSpecification
Temperature Resistance500°C, continuous operation 1h
IndustryMetallurgy/glass industry specialized
DesignSpecial fireproof materials + water-cooled bearings

XFJ-FR-B Series Explosion-Proof Fire Fan

ParameterSpecification
Explosion-ProofEx d IIB T4 Gb explosion-proof certification
EnvironmentChemical plants/gas stations specialized
FeatureMeets both fire and explosion-proof requirements

Selection Guide

By Installation Position

TypeInstallation PositionAir Volume RangeXinfeng Model
Roof Fire Smoke Exhaust FanRoof5,000-50,000 m³/hXFJ-FR-T
Ceiling Fire Smoke Exhaust FanInside ceiling3,000-30,000 m³/hXFJ-FR-D
Vertical Fire Smoke Exhaust FanMachine room10,000-100,000 m³/hXFJ-FR-V
Duct Fire Smoke Exhaust FanIn duct2,000-20,000 m³/hXFJ-FR-P

Selection Parameters

ParameterDescriptionXinfeng Configuration
Exhaust VolumeCalculated by GB51251 formulaSpace volume × air change rate
Exhaust Temperature280°C (flue gas temperature)Fireproof design
Total Pressure≥500Pa (considering pipeline resistance)Multi-impeller series
Motor Power1.2x safety factor2.2-75kW

Xinfeng Fire Fan Advantages

AdvantageDescription
Full Product Line CCCF CertificationCertificates complete
Complete Fire Resistance Test ReportsCan respond to fire inspection
System Design SolutionsEnsure smoke exhaust effectiveness
24-Hour Emergency ServiceFire equipment allows no compromise
2-Year WarrantyLifetime maintenance

Frequently Asked Questions

Q: Does the fire fan require regular testing?

A: Yes. Monthly manual start test, quarterly automatic start test, annual comprehensive inspection. Xinfeng provides annual maintenance services.

Q: What is the difference between fire smoke exhaust fan and supply fan?

A: Fire smoke exhaust fan expels smoke, supply fan sends positive pressure to evacuation passages. They work together to form a complete smoke management system.

Q: How long is the fire fan certification valid?

A: CCCF certification valid for 5 years, requires renewal. Xinfeng certificates remain valid and can be verified at any time.

Q: What is the delivery time for Xinfeng fire fans?

A: Standard models 10-15 days, custom models 20-30 days. Fire equipment urgent orders prioritized.