Fan Startup Preparation  

1: Check whether the fan's regulating damper and inlet/outlet dampers are open;  

2: Manually rotate the fan to inspect component clearances and check for friction between the impeller and casing;  

3: Ensure coupling guards and pulley guards are properly installed;  

4: Verify bearing housing oil level meets operational lubrication requirements; 5: For fans with water-cooled bearings, verify adequate cooling water supply; 6: Electrically confirm fan rotation direction while inspecting for leaks (water/oil), vibration, abnormal noises, or unusual odors.


5b3f4efc3091060792448d58bdcf91d7

02

Fan Startup

1: Start the fan (monitor for smooth operation);

2: After startup, gradually open the damper to the airflow required for actual production. Monitor the motor operating current during damper opening to prevent overload caused by excessive damper opening;

3: After startup, monitor the fan bearing temperature. Bearing temperature rise must not exceed 40 degrees above the ambient temperature at the site.

251360d6053b6b28891bd5499d66a12c

03  

Inspection During Fan Operation  

1: Listen for smooth operation, unusual noises, or friction;  

2: Check all anchor bolts for looseness; 3: Check bearing temperature and lubrication status; 4: Verify bearing lubricant cooling water flow is unobstructed and inspect inlet/outlet pipes for temperature differences; 5: Check for lubricant leakage from the bearing housing; 6: Listen for abnormal noises from the bearing housing and bearings during operation, and ensure smooth rotation; 7: Verify stable operating current.

42878975bee645386f6c6a7eadcd0ccb

0 4

Emergency Stop 

1: Detection of severe noise from the fan; 

2: Friction between the impeller and casing;

3: Sudden intensification of casing vibration; 

4: Continuous bearing temperature rise exceeding permissible limits; 

5: Sudden surge in current that does not recover within 2 minutes; 

6: Severe oil leakage from the bearing housing; 

7: Cooling water interruption lasting over 30 minutes.

fea4105af04417df133e8f4f7a571bd2

0 5      

Fan Shutdown

     1: Reduce load before stopping fan operation;

 2: Close cooling water inlet and outlet valves; 

3: If conveying hot air, stop the heater first and wait until the fan outlet temperature drops to 40°C before stopping the fan; 

4: After fan shutdown, open the drain valve at the bottom of the casing to drain water; simultaneously close the fan inlet and outlet dampers.